Support: 214-635-4855

Email: sales@veilux.net

🇺🇸 English
🇪🇸 Español
🇸🇦 عربي
🇻🇳 Tiếng Việt
🇲🇾 Bahasa Melayu

SKU: SVEX-PIP-2M-35MM

SVEX-PIP-2M-35MM 2MP Explosion-proof Thermal PTZ Camera

2MP explosion-proof thermal PTZ camera with 36x optical zoom, 8–14μm wavelength, IP68-rated 304/316L stainless steel housing, and smart windshield wiper.

2MP

Image Resolution

4.3-129 mm

Motorized Lens

36x

Optical Zoom

304

Stainless Steel

Explosion-proof for Hazardous Industrial Areas

Explosion-proof for Hazardous Locations

This explosion-proof is ATEX and IECEx certified for Class I Division 1 and Zone 1 hazardous locations including oil and gas refineries, chemical plants, and offshore platforms. Designed to contain any internal ignition and prevent it from igniting surrounding flammable atmospheres.

explosion proof

All Veilux products comply with international IECEx standards for hazardous area certification.

Technical Specifications & Ordering

This explosion-proof explosion-proof is available for immediate quotation. Veilux provides full technical documentation, dimensional drawings, and certification copies upon request. Standard configurations ship from stock; custom modifications are available for specialized hazardous area installations. Contact Veilux for project pricing, volume discounts, and compatibility verification for your specific application.

Explosion-Proof Explosion-proof Performance & Reliability

The explosion-proof explosion-proof design delivers consistent performance in the most demanding industrial environments, backed by comprehensive certification documentation and Veilux technical support.

Explosion-proof for Hazardous Locations

This explosion-proof explosion-proof is engineered for hazardous locations where standard equipment cannot operate safely. Certified for Class I Division 1 and Division 2 environments, it meets ATEX and IECEx standards for oil & gas, chemical, mining, and offshore installations.

Explore the full Veilux range of explosion-proof security cameras for your industrial security requirements.

Certifications & Compliance Standards

This explosion-proof explosion-proof complies with international safety standards including ATEX Directive 2014/34/EU for European hazardous area equipment and IECEx system certification for global acceptance. The product meets NEC Article 500 classification requirements for Class I Division 1 and Division 2 hazardous locations in North America, ensuring safe operation in environments containing flammable gases and vapors. All certifications are maintained through regular third-party audits by accredited testing laboratories.

Industrial Applications

Designed for the most demanding industrial environments, this explosion-proof is used in oil and gas refineries, petrochemical processing facilities, chemical manufacturing plants, pharmaceutical production areas, offshore platforms, and underground mining operations. It delivers reliable performance in Zone 1 and Zone 2 areas under IEC 60079, and in Class I Division 1 and Division 2 locations. Facility managers and HSE engineers rely on Veilux explosion-proof solutions to maintain safety and security in hazardous environments without compromising operational efficiency.

Why Choose Veilux?

Veilux has over 15 years of expertise designing explosion-proof security and monitoring equipment for hazardous environments. Our engineering team works directly with oil and gas operators, safety engineers, and facility managers to develop products that meet the most stringent safety and performance requirements. Every Veilux explosion-proof is backed by comprehensive technical support, detailed installation documentation, and global certification coverage to simplify procurement and compliance verification for international projects.

Key Features

  • Certified explosion-proof for Zone 1 / Class I Division 1 environments
  • ATEX, IECEx, and UL listed explosion-proof for global compliance
  • Rugged industrial-grade construction for harsh environments
  • Wide operating temperature range for extreme conditions

For technical specifications, certifications, and pricing on this explosion-proof, browse the full Veilux explosion-proof product range or contact our hazardous area specialists.

Explosion-proof: Certifications and Compliance Standards

This explosion-proof meets the most stringent international hazardous area standards, ensuring safe operation in explosive atmospheres worldwide.

  • ATEX Directive 2014/34/EU: Certifies this explosion-proof for Zone 1 and Zone 2 hazardous areas in Europe.
  • IECEx System: Internationally recognised certification for this explosion-proof across 60+ countries.
  • UL/cUL Listed: North American approval for Class I Division 1 and Division 2 environments.
  • NFPA 70 / NEC Compliant: Meets National Electrical Code requirements for hazardous locations.
  • IP66 / IP67: Dust-tight and waterproof ingress protection for harsh industrial environments.

Industries Using This Explosion-proof

This explosion-proof is widely deployed across oil and gas refineries, petrochemical plants, offshore platforms, pharmaceutical facilities, grain elevators, paint spray booths, and wastewater treatment facilities. For detailed explosion-proof compliance guidance, refer to IEC international standards and NFPA codes.

Contact Veilux for custom explosion-proof configurations, bulk pricing, and technical certification documentation.

Applications for This Explosion-proof

This explosion-proof is engineered for the most demanding industrial environments where conventional cameras would pose an ignition risk. Typical deployment sites for this explosion-proof include:

  • Oil and Gas Refineries – Perimeter and process area monitoring with this explosion-proof rated for Class I Division 1 zones containing hydrocarbon vapors.
  • Offshore Platforms and FPSOs – Marine-grade explosion-proof with ATEX Zone 1 certification for wellhead, deck, and module surveillance.
  • Chemical and Petrochemical Plants – 24/7 process monitoring using this explosion-proof in areas handling flammable solvents and reactive chemicals.
  • Pharmaceutical Manufacturing – This explosion-proof supports compliance monitoring in ATEX Zone 2 solvent and API production areas.
  • Grain Elevators and Food Processing – Dust-rated explosion-proof for Class II Division 1 environments with combustible grain or sugar dust.
  • Paint Spray Booths – Continuous surveillance using this explosion-proof in NFPA 33 compliant spray finishing enclosures.
  • Wastewater Treatment – This explosion-proof monitors digester and pump station areas where methane accumulation creates explosion risk.

Contact Veilux to confirm this explosion-proof is the right fit for your hazardous area classification and application requirements. Our engineers can assist with zone drawings, equipment selection, and customised explosion-proof quotations.

Frequently Asked Questions

What certifications apply?

This unit meets ATEX Directive 2014/34/EU, IECEx, UL 1203, and CSA standards for explosive atmospheres. Certificates of conformity, test reports, and declarations are available on request from Veilux.

What temperature range is supported?

Operating range varies by model, typically -40C to +75C ambient. Each unit carries a T-class rating defining maximum surface temperature. Consult the datasheet and compare with the auto-ignition temperature of substances present in your classified area before installation.

Is ONVIF compatibility included?

Yes. ONVIF Profile S and Profile G compliance ensures interoperability with Milestone XProtect, Genetec Security Center, Avigilon Control Center, and Hanwha Wisenet WAVE. Custom SDK integration is available for enterprise projects requiring analytics overlays or access control system tie-ins.

What wiring methods apply for Class I Division 1?

NEC Article 501 requires threaded rigid metal conduit with listed conduit seals within 450 mm of each enclosure. All seals must be filled with approved compound before energising. Flexible connections require listed flexible fittings rated for the division and applicable gas group of the installation area.

What power options are available?

Units are available in 24V AC, 24V DC, 110-240V AC, and PoE+ (IEEE 802.3at, 30W) variants by model. PoE+ simplifies installation by delivering both power and data over a single CAT6 cable run through the conduit system.

How is maintenance performed in hazardous areas?

IEC 60079-17 defines visual, close, and detailed inspection grades at site-scheduled intervals. Technicians should verify enclosure threads, flameproof gap dimensions, gasket condition, conduit seal integrity, cable entry tightness, and external grounding continuity. All maintenance must be performed by a CompEx-certified technician to retain certification status.

Can it be used outdoors?

Yes. IP66/IP67 ingress protection ensures suitability for rain, high-pressure washdown, and dusty environments. UV-stabilised materials prevent degradation in direct sunlight. Stainless steel hardware resists salt-spray corrosion for marine and coastal platform deployments.

What are the warranty and delivery terms?

Standard stocked configurations ship within 3-5 business days from our Grand Prairie, Texas facility. Custom configurations and large orders may require 2-4 weeks. All products carry a two-year limited warranty against manufacturing defects. Extended service contracts and volume pricing are available from the Veilux sales team.

All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.

Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.

Professional installation is strongly recommended for all hazardous-area equipment. Installers experienced with NEC Article 500 and IEC 60079 can verify that cable entries, conduit seals, and grounding connections are completed correctly and documented for compliance records. Veilux supplies full technical documentation, certified installation drawings, wiring diagrams, and post-installation support for every product in our catalog at no additional charge.

Routine inspection and preventive maintenance extend service life and preserve explosion-proof certifications. Key inspection points include housing integrity, cable gland condition, lens or cover glass condition, and confirmation that all enclosure fasteners meet published torque specifications. Veilux can assist with scheduled maintenance programs tailored to your facility type, operating cycle, and regulatory requirements, helping reduce unplanned downtime and extend the useful life of each installed unit.

Custom configurations are available for non-standard mounting geometries, extreme temperature ranges, or unique area classifications. Veilux engineers work directly with facility managers, EHS officers, and project engineers to develop solutions that meet both performance targets and compliance obligations. Contact our technical team to discuss your specific project requirements and receive a detailed equipment proposal, including complete bill of materials and compliance documentation for your approval process.

All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.

Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.

Professional installation is strongly recommended for all hazardous-area equipment. Installers experienced with NEC Article 500 and IEC 60079 can verify that cable entries, conduit seals, and grounding connections are completed correctly and documented for compliance records. Veilux supplies full technical documentation, certified installation drawings, wiring diagrams, and post-installation support for every product in our catalog at no additional charge.

Routine inspection and preventive maintenance extend service life and preserve explosion-proof certifications. Key inspection points include housing integrity, cable gland condition, lens or cover glass condition, and confirmation that all enclosure fasteners meet published torque specifications. Veilux can assist with scheduled maintenance programs tailored to your facility type, operating cycle, and regulatory requirements, helping reduce unplanned downtime and extend the useful life of each installed unit.

Custom configurations are available for non-standard mounting geometries, extreme temperature ranges, or unique area classifications. Veilux engineers work directly with facility managers, EHS officers, and project engineers to develop solutions that meet both performance targets and compliance obligations. Contact our technical team to discuss your specific project requirements and receive a detailed equipment proposal, including complete bill of materials and compliance documentation for your approval process.

 

Certificate
ATEXII 2G Ex d IIC T6 Gb
II 2D Ex tb IIIC IP68 T80℃ Db
Ingress Protection LevelIP66
Sensor
Wavelength8~14μm
Detector640×512, 25Hz uncooled FPA Vox Detector (exchangeable camera module)
Thermal Imager
Thermal Lens35mm fixed
Rotation RangeHorizontal: 0~360°, Vertical: ±90°
Image ProcessingAGC, DDE
PTZ Function
Rotation SpeedHorizontal: 0.1°/s ~ 40°/s, Vertical: 0.1°/s ~ 40°/s
Monitoring Location300 locations can be set
Monitoring Location Setting Accuracy±0.1°
Communication
ProtocolPelco-D, Pelco-P, etc.
Baud Rate2400 / 4800 / 9600 bps
Communication MethodRS485
Lens
Focal Distance4.3–129mm, 36x
Horizontal View Angle65.5°–2.11° (Wide–Tele)
ApertureF1.6 – F5.0
Zoom SpeedApprox. 3s (Optical Wide–Tele)
Min Working Distance10–1500mm (Wide–Tele)
Other Specifications
NETD≤50mK@F1.0, 300K
Atmospheric Pressure80kPa~106kPa
Temperature Range-40°C ~ +60°C
Relative Humidity≤95% (+25°C)
Supply VoltageAC220V
Material304 stainless steel (Optional: 316, 316L)
Inlet Hole SpecificationsG-3/4″ × 1
Electrical Connection10-core composite cable
WindowΦ65mm
Inner SizeΦ100 × 230mm
Installation MethodBracket or base installation
Thermostat SystemOptional

SVEX-PIP-2M-35MM Spec Sheet

SVEX-PIP-2M-35MM User Manual