Axis Communications manufactures industry-leading IP cameras trusted across commercial and industrial applications. However, standard Axis cameras carry no ATEX, IECEx, or NEC Class I Division 1 certification and cannot be installed directly in hazardous classified areas. The solution used by system integrators worldwide is to use Axis camera explosion-proof housings, which is an Axis camera module inside a Veilux ATEX/IECEx certified explosion-proof housing — combining Axis imaging performance with proven explosion protection.
Compatible Axis Camera Models
The following Axis box-style and module cameras fit inside Veilux Axis camera explosion-proof housings. All require a Veilux housing with a compatible lens port (CS-mount or C-mount adapter available).
| Model | Resolution | Sensor | Lens Mount | Operating Temp | Recommended Veilux Housing |
|---|---|---|---|---|---|
| AXIS P1375 | 5MP (2592×1944) | 1/2.8″ CMOS | CS-mount | -30°C to +50°C | Veilux Explosion-Proof Box Housing |
| AXIS Q1615 Mk III | 1080p Full HD | 1/2.8″ CMOS | CS-mount | -40°C to +65°C | Veilux Explosion-Proof Box Housing |
| AXIS P1377 | 5MP | 1/2.8″ CMOS | CS-mount | -30°C to +50°C | Veilux Explosion-Proof Box Housing |
| AXIS Q1700-LE | 2MP LPR | 1/2.8″ CMOS | CS-mount | -40°C to +65°C | Veilux Explosion-Proof Box Housing |
| AXIS P1448-LE | 8MP multi-sensor | 1/2.5″ CMOS | Fixed multi-lens | -50°C to +60°C | Veilux Wide-Angle Housing (custom) |
How the Integration Works
Veilux explosion-proof housings are ATEX Zone 1 / IECEx Ex d IIC T6 certified and accept industry-standard camera modules through a front lens port. The Axis camera is mounted on the internal camera tray, the lens is threaded through the housing window port, and PoE or 24VAC power is run through an explosion-proof conduit entry. The Veilux housing provides the gas-tight enclosure required for Class I Division 1 and Zone 1 compliance — the Axis camera provides the imaging capability.
Integration Requirements
- Conduit entry: All cable entries must use explosion-proof conduit seals (EYS fittings per NEC 501.15)
- Lens port: CS-mount cameras use the standard 1″ clear borosilicate glass window port; C-mount adapter available
- Power: PoE (802.3at) or 24VAC supplied through explosion-proof junction box
- Camera settings: Axis camera is configured via AXIS Device Manager or AXIS Camera Station before housing installation
Benefits of Axis + Veilux vs. Native Axis Explosion-Proof Cameras
- Access to Axis’s full camera line (including latest 4K and thermal models) without waiting for ATEX certification
- Familiar Axis interface for operators already running AXIS Camera Station or third-party VMS
- Veilux housings are independently certified — swap camera models without re-certifying the installation
- Cost advantage over purpose-built explosion-proof PTZ cameras for fixed-mount applications
Frequently Asked Questions
- Does placing an Axis camera in a Veilux housing create a certified explosion-proof assembly?
- The Veilux housing carries ATEX and IECEx Ex d certification. The certification covers the housing as a protective enclosure. The camera module inside is not individually certified, but the complete assembly (housing + camera) meets the requirements when installed per the housing certification documentation. Consult your area classification authority for site-specific requirements.
- Which Axis cameras are NOT suitable for housing integration?
- Axis dome and bullet cameras with integrated outdoor enclosures are not suitable — their fixed lens and molded body cannot be separated from the outer housing. Only box-style cameras with removable CS-mount lenses are compatible. PTZ cameras require a Veilux explosion-proof PTZ housing with slip-ring power feed.
- Can I use AXIS Camera Station with a Veilux-housed Axis camera?
- Yes. The Axis camera inside the Veilux housing connects to your network exactly like any Axis camera. AXIS Camera Station, AXIS Device Manager, and any ONVIF-compatible VMS will recognize it and manage it normally.
Ready to specify Axis cameras for your hazardous-area installation? Browse our explosion-proof housings or request a quote with your Axis model and site classification details.
Further Reading
- Explosion-Proof Camera Housing Selection Guide
- Explosion-Proof Camera Network Architecture and VLAN Guide
- NVR Selection for Explosion-Proof CCTV Systems
- Explosion-Proof IP Camera Video Analytics
- Browse Explosion-Proof Camera Housings
- Request a Project Quote
For regulatory standards on explosion-proof, refer to the OSHA hazardous location standards and NFPA 70 National Electrical Code.

All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.
Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.
Professional installation is strongly recommended for all hazardous-area equipment. Installers experienced with NEC Article 500 and IEC 60079 can verify that cable entries, conduit seals, and grounding connections are completed correctly and documented for compliance records. Veilux supplies full technical documentation, certified installation drawings, wiring diagrams, and post-installation support for every product in our catalog at no additional charge.
Routine inspection and preventive maintenance extend service life and preserve explosion-proof certifications. Key inspection points include housing integrity, cable gland condition, lens or cover glass condition, and confirmation that all enclosure fasteners meet published torque specifications. Veilux can assist with scheduled maintenance programs tailored to your facility type, operating cycle, and regulatory requirements, helping reduce unplanned downtime and extend the useful life of each installed unit.
Custom configurations are available for non-standard mounting geometries, extreme temperature ranges, or unique area classifications. Veilux engineers work directly with facility managers, EHS officers, and project engineers to develop solutions that meet both performance targets and compliance obligations. Contact our technical team to discuss your specific project requirements and receive a detailed equipment proposal, including complete bill of materials and compliance documentation for your approval process.
All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.
Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.
Professional installation is strongly recommended for all hazardous-area equipment. Installers experienced with NEC Article 500 and IEC 60079 can verify that cable entries, conduit seals, and grounding connections are completed correctly and documented for compliance records. Veilux supplies full technical documentation, certified installation drawings, wiring diagrams, and post-installation support for every product in our catalog at no additional charge.
Routine inspection and preventive maintenance extend service life and preserve explosion-proof certifications. Key inspection points include housing integrity, cable gland condition, lens or cover glass condition, and confirmation that all enclosure fasteners meet published torque specifications. Veilux can assist with scheduled maintenance programs tailored to your facility type, operating cycle, and regulatory requirements, helping reduce unplanned downtime and extend the useful life of each installed unit.