VL-EXS8230-XX Explosion-Proof Short Emergency Light (10W–30W)
The Veilux VL-EXS8230-XX is a compact explosion-proof emergency light built for Class I Division 1, Division 2, ATEX Zone 1, and Zone 2 hazardous areas requiring battery-backed emergency illumination. Its short-profile housing fits in confined and low-clearance installation locations — process corridors, equipment mezzanines, and sub-deck spaces on offshore platforms — where standard-length emergency fixtures cannot be mounted.
The unit delivers reliable emergency illumination for a minimum of 90 minutes on battery backup, satisfying NFPA 101, NFPA 70E, and OSHA 29 CFR 1910.303 requirements for emergency lighting in classified areas.
Technical Specifications
| Specification | Value |
|---|---|
| Power Range | 10W / 20W / 30W (select at order) |
| Emergency Battery | Ni-MH rechargeable, minimum 90-minute backup |
| Input Voltage | AC 100–277V, 50/60Hz |
| IP Rating | IP66 |
| Housing Material | Aluminum alloy (compact short-profile form) |
| LED Lifespan | 50,000 hours |
| Operating Temperature | -20°C to +55°C |
| T-Code | T5 (max surface 100°C) |
| Self-Test | Automatic monthly function test with LED indicator |
| Dimensions (L×W×H) | Short-profile — see datasheet for exact dimensions |
| Cable Entry | M20 Ex-rated cable gland (2 entries) |
Certifications & Compliance
| Standard | Classification | Region |
|---|---|---|
| UL 1203 / cUL | Class I Division 1 & 2 | North America |
| ATEX | II 2 G Ex d IIC T5 Gb | European Union |
| IECEx | Ex d IIC T5 Gb | International |
| IP66 | Dust-tight, high-pressure jet-proof | IEC 60529 |
| NFPA 101 / NFPA 70E | Emergency egress lighting code compliance | North America |
Applications
- Emergency egress and escape route lighting in refineries and chemical plants
- Sub-deck emergency lighting on offshore platforms
- Low-clearance process corridors and tunnels where standard-length fixtures don’t fit
- Equipment mezzanines and classified pump rooms
- Backup illumination for control rooms in Division 2 or Zone 2 areas
Frequently Asked Questions
What is the battery backup duration?
The VL-EXS8230-XX provides a minimum of 90 minutes of emergency illumination on fully charged battery backup — meeting NFPA 101 and OSHA egress lighting requirements.
Does the fixture perform automatic self-tests?
Yes. The unit includes an automatic monthly function test and annual 90-minute duration test. Results are displayed via front-panel LED indicator (green = normal, red = fault).
What is the difference between the VL-EXS8230-XX and the VL-EX8236B-ELB emergency light?
The VL-EXS8230-XX uses a short compact housing for low-clearance installations and provides 10–30W output. The VL-EX8236B-ELB is a larger emergency light with extended battery capacity and wider beam coverage for open process areas.
Related Resources
Explosion-Proof LED Lights: Complete Buyer’s Guide
Explosion-Proof Equipment Compliance Checklist
Certification Guide: UL, ATEX & IECEx Explained
Certifications & Standards: NFPA 70 — National Electrical Code (NEC) · IECEx International Certification System · EU ATEX Directive 2014/34/EU