Explosion Proof Cameras
Veilux explosion-proof cameras are certified to ATEX, IECEx, UL Class I Division 1, and cUL standards for safe surveillance in oil and gas, chemical, mining, pharmaceutical, and offshore hazardous environments. All housings are engineered with flame-path protection that contains any internal ignition before it can propagate to a surrounding explosive atmosphere.
Selecting the right explosion-proof camera requires matching the camera’s certification to the specific Class, Division (or Zone), and Group classification of each installation area. Start with the complete camera selection guide, or jump to a specific topic:
Class 1 Division 1 vs Division 2: Camera Selection Guide
Intrinsically Safe vs Explosion-Proof Cameras
ATEX Zone 0, Zone 1, Zone 2: Camera Selection Guide
Explosion-Proof Camera Housing Selection Guide
How to Design a Hazardous Area CCTV System
Categories
All Products
- IP68
- 2MP
- 100 m (328 ft)
- Motorized
- 30x
- Ex d II CT6 Gb/ Ex tD A21 IP68 T80° C
- 2MP
- Motorized
- 33x
- Exd ⅡC T6 Gb / Ex tD A21 IP68 T80℃
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- ATEX II 2G Ex d IIC T6 Gb II 2D Ex tb IIIC IP68 T80°C Db
- 2MP
- 100 m (328 ft)
- Motorized
- 18x
- Ex II 2G Ex db op or II C T6 Gb/Ex II 2D Ex tb op pr II C T80 ºC Db
- 2MP
- Motorized
- 30x
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- 2G Ex db IIC T6 Gb/2D Ex tb IIC T80ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex dIIC T6 Gb/Ex tD A21 IP68 T80°C
- 5MP
- 200 m (656 ft)
- Motorized
- 30x
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 4MP
- 40 m (131 ft)
- Motorized
- 4x
- Exd II C T6 GB/DIP A20 TA T6
- 700TVL
- Motorized
- 36x
- Ex db IIC T6 Gb/ Ex tb IIIC T80℃ Db
- 8MP
- 60 m (197 ft)
- Motorized
- ATEX II 2G Ex d IIC T6 Gb II 2D Ex tb IIIC IP68 T80°C Db
- 2MP
- 100 m (328 ft)
- Motorized
- 18x
- Ex II 2G Ex db op or II C T6 Gb/Ex II 2D Ex tb op pr II C T80 ºC Db
- 2MP
- Motorized
- 30x
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex db IIC T6 Gb/ Ex tb IIIC T80℃ Db
- 8MP
- 60 m (197 ft)
- Motorized
- Exd IIC T6 GB/DIP A20 TA, T6
- 700TVL
- 30 m (98 ft)
- Motorized
- 36x
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 2MP
- 30 m (98 ft)
- Fixed
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 2MP
- 30 m (98 ft)
- Fixed
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 2MP
- 30 m (98 ft)
- Motorized
- Ex db IIC T6 Gb/ Ex tb IIIC T80℃ Db
- 8MP
- 60 m (197 ft)
- Motorized
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex II 2G Ex db op is IIC T6 Gb/Ex2D Ex tb op is IIC T80 ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 4MP
- 40 m (131 ft)
- Motorized
- 4x
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- 4MP
- 40 m (131 ft)
- Motorized
- 4x
- IP68
- 2MP
- 100 m (328 ft)
- Motorized
- 30x
- Ex d II CT6 Gb/ Ex tD A21 IP68 T80° C
- 2MP
- Motorized
- 33x
- Exd ⅡC T6 Gb / Ex tD A21 IP68 T80℃
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- 2G Ex db IIC T6 Gb/2D Ex tb IIC T80ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- Ex dIIC T6 Gb/Ex tD A21 IP68 T80°C
- 5MP
- 200 m (656 ft)
- Motorized
- 30x
- Exd II C T6 GB/DIP A20 TA T6
- 700TVL
- Motorized
- 36x
- ExdIIC T6 Gb/Ex tD A21 IP68 T80°C
- 2MP
- Motorized
- 30x
- Exd II C T6 Gb/Ext DA21 IP68 T80°C
- 2MP
- Motorized
- 32x
- Ex dIIC T6 Gb/Ex tD A21 IP68 T80°C
- 5MP
- 200 m (656 ft)
- Motorized
- 30x
- 2G Ex db IIC T6 Gb/2D Ex tb IIC T80ºC Db
- 2MP
- 200 m (656 ft)
- Motorized
- 30x
- IP68
- 2MP
- 100 m (328 ft)
- Motorized
- 30x
- 2G Ex db IIC T6 Gb/2D Ex tb IIC T80ºC Db
- 2MP
- Motorized
- 20x