SKU: SVEX-B25Z-Z
SVEX-B25Z-Z Explosion-Proof Bullet Camera with Infrared Light
- Class I Div I
- Stainless steel 304 or 316L corrosion proof for marine area
- Enclosure Protection: IP68
- Fit for gas zone 1, zone 2, dust zone 21, 22
- Motorized lens 2.8-12mm
- Available in 2MP or 4MP Resolution
Note: This is a special order item. Allow 4-6 weeks for delivery.
4MP
Image Resolution
2.8-12 mm
Motorized Lens
30 m (98 ft)
IR Range
304
Stainless Steel
Explosion-proof Bullet Camera for Hazardous Industrial Areas
Explosion-proof bullet camera for Hazardous Locations
This explosion-proof bullet camera is ATEX and IECEx certified for Class I Division 1 and Zone 1 hazardous locations including oil and gas refineries, chemical plants, and offshore platforms. Designed to contain any internal ignition and prevent it from igniting surrounding flammable atmospheres.

Features:
- Class I Div I
- Stainless steel 304 or 316L corrosion proof for marine area
- Optional electropolished or corrosion resistant paint finish
- Enclosure Protection: IP68
- Exd II CT6 Gb/ Ex tD A21 IP68 T80°C
- Fit for gas zone 1, zone 2, dust zone 21, 22
- Power input: DC12V or POE power supply
- With lights for night vision: 0-30m distance
- Camera: 2MP vari-focal bullet camera
- Motorized lens 2.8-12mm
- Optional Audio/alarm I/O
- Application: gas zone 1, 2; dust zone 21, 22.
- Available in 2MP or 4MP Resolution
Certifications & Standards: IECEx International Certification System · EU ATEX Directive 2014/34/EU
Svex for Hazardous Locations
This explosion-proof svex is engineered for hazardous locations where standard equipment cannot operate safely. Certified for Class I Division 1 and Division 2 environments, it meets ATEX and IECEx standards for oil & gas, chemical, mining, and offshore installations.
Explore the full Veilux range of explosion-proof lighting for your industrial security requirements.
Certifications & Compliance Standards
This explosion-proof explosion complies with international safety standards including ATEX Directive 2014/34/EU for European hazardous area equipment and IECEx system certification for global acceptance. The product meets NEC Article 500 classification requirements for Class I Division 1 and Division 2 hazardous locations in North America, ensuring safe operation in environments containing flammable gases and vapors. All certifications are maintained through regular third-party audits by accredited testing laboratories.
Industrial Applications
Designed for the most demanding industrial environments, this explosion is used in oil and gas refineries, petrochemical processing facilities, chemical manufacturing plants, pharmaceutical production areas, offshore platforms, and underground mining operations. It delivers reliable performance in Zone 1 and Zone 2 areas under IEC 60079, and in Class I Division 1 and Division 2 locations. Facility managers and HSE engineers rely on Veilux explosion solutions to maintain safety and security in hazardous environments without compromising operational efficiency.
Why Choose Veilux?
Veilux has over 15 years of expertise designing explosion-proof security and monitoring equipment for hazardous environments. Our engineering team works directly with oil and gas operators, safety engineers, and facility managers to develop products that meet the most stringent safety and performance requirements. Every Veilux explosion is backed by comprehensive technical support, detailed installation documentation, and global certification coverage to simplify procurement and compliance verification for international projects.
Explosion-Proof Explosion Performance & Reliability
The explosion-proof explosion design delivers consistent performance in the most demanding industrial environments, backed by comprehensive certification documentation and Veilux technical support.
Key Features
- Certified explosion-proof bullet camera for Zone 1 / Class I Division 1 environments
- ATEX, IECEx, and UL listed explosion-proof bullet camera for global compliance
- Rugged industrial-grade construction for harsh environments
- Wide operating temperature range for extreme conditions
For technical specifications, certifications, and pricing on this explosion-proof bullet camera, browse the full Veilux explosion-proof product range or contact our hazardous area specialists.
Explosion-proof Bullet Camera: Certifications and Compliance Standards
This explosion-proof bullet camera meets the most stringent international hazardous area standards, ensuring safe operation in explosive atmospheres worldwide.
- ATEX Directive 2014/34/EU: Certifies this explosion-proof bullet camera for Zone 1 and Zone 2 hazardous areas in Europe.
- IECEx System: Internationally recognised certification for this explosion-proof bullet camera across 60+ countries.
- UL/cUL Listed: North American approval for Class I Division 1 and Division 2 environments.
- NFPA 70 / NEC Compliant: Meets National Electrical Code requirements for hazardous locations.
- IP66 / IP67: Dust-tight and waterproof ingress protection for harsh industrial environments.
Industries Using This Explosion-proof Bullet Camera
This explosion-proof bullet camera is widely deployed across oil and gas refineries, petrochemical plants, offshore platforms, pharmaceutical facilities, grain elevators, paint spray booths, and wastewater treatment facilities. For detailed explosion-proof bullet camera compliance guidance, refer to IEC international standards and NFPA codes.
Contact Veilux for custom explosion-proof bullet camera configurations, bulk pricing, and technical certification documentation.
All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.
Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.
| Camera | |
|---|---|
| Atmospheric Pressure | 80KPa~110Kpa |
| Ambient Temperature | –20°C~+60°C |
| Relative Humidity | ≤95% (+25°C) |
| Ex-proof Mark | Exd II CT6 Gb/ Ex tD A21 IP68 T80°C |
| Hazardous Location Classification | Class I Div I |
| Explosion Proof Certified | CNEx 16.2526 |
| Ingress Protection | IP68 |
| Housing Material | Stainless Steel 304 or 316L |
| Image Sensor | 1/2.7″ Progressive Scan CMOS |
| Max. Image Resolution | 2.0 megapixel |
| Frame Rate | Main Stream: 1080P (1920×1080), Max 30fps; Sub Stream: 720P (1280×720), Max 30fps; Third Stream: D1 (704×576), Max 30fps |
| Min. Illumination | 0.01Lux @(F1.6, AGC ON), 0 Lux with IR |
| Shutter | Auto/Manual, 1/100,000 sec |
| Lens | 2.8 – 12 mm, motorized lens |
| DORI Distance | |
| DORI Distance | Detect: 2.8mm – 42m; 12mm – 180m Observe: 2.8mm – 16.8m; 12mm – 72m Recognize: 2.8mm – 8.4m; 12mm – 36m Identify: 2.8mm – 4.2m; 12mm – 18m |
| Angle of View (H) | 112.7° – 28.1° |
| Angle of View (V) | 60.1° – 15.4° |
| Angle of View (O) | 146.5° – 33.2° |
| Day & Night | IR cut filter with auto switch |
| S/N Ratio | >52dB |
| Image Enhancement | 2D/3D DNR |
| HLC, BLC | Supported |
| OSD | Up to 4 OSDs |
| Privacy Mask | Up to 8 areas |
| ROI | Up to 2 areas |
| Motion Detection | Up to 4 areas |
| WDR | DWDR |
| Video Output | 1 RJ45 100M Base-TX Ethernet |
| Edge Storage | MicroSD, Up to 256GB |
| Video Compression | Ultra 265, H.265, H.264, MJPEG |
| H.264 Type | Baseline Profile, Main Profile |
| Compatible Integration | ONVIF (Profile S, Profile G, Profile T), API |
| Protocols | IPv4, IGMP, ICMP, ARP, TCP, UDP, DHCP, RTP, RTSP, RTCP, DNS, DDNS, NTP, FTP, UPnP, HTTP, HTTPS, SMTP, SSL, QoS |
| Light Night Vision | 0-30m |
| Voltage Input | DC 12V±25%, PoE (IEEE 802.3af) |
| Power Consumption | 7.5W Max |
| Cable Output | Integrated cable, 2m long |
| Cable Gland | 1pcs G3/4 or M25×1.5 |
| Overall Dimension | 319×144×168mm (L×W×H) |
| Net Weight | 7.5 kg |
Get a Free Customized Quote
Looking for pricing or have questions about this product? Fill out the form below and a member of our team will get back to you shortly.