SKU: SVEX-T400B-18Z 304
SVEX-T400B-18Z Explosion-Proof Motorized Bullet Camera with 18x Zoom
Explosion-Proof Motorized Bullet Camera with 18x zoom and stainless steel housing for hazardous gas and dust areas.
2MP
Image Resolution
4.7-84.6 mm
Motorized Lens
18x
Optical Zoom
100 m (328 ft)
IR Range
304
Stainless Steel
Explosion-proof Motor for Hazardous Industrial Areas
Explosion-proof motor for Hazardous Locations
This explosion-proof motor is ATEX and IECEx certified for Class I Division 1 and Zone 1 hazardous locations including oil and gas refineries, chemical plants, and offshore platforms. Designed to contain any internal ignition and prevent it from igniting surrounding flammable atmospheres.

The Veilux SVEX-T400B-18Z Explosion-Proof Motorized Bullet Camera with 18x Zoom
Features:- SONY 1/2.8″ CMOS Sensor CCD ,resolution up to 1920 x 1080 pixel
- 18x optical zoom, automatic aperture, automatic focusing, easy to monitor remote targets
- Super Low Lux. Color: 0.05Lux/F1.6; BW: 0.01Lux/F1.6
- Supports D-WDR, 3D-DNR, low-bit rate
- ICR Day/Night Auto-switch, Color/BW, 24hr monitoring
- High quality IR, long service life, low power consumption, IR range up to 100 meters
- Low power consumption, the heat dissipation design, can work continuously
- Usual: AC220V/DC12V, other Power mode can be customized
- Made of 304 stainless steel material (316 and 316L Optional)
- Explosion-proof, anti-corrosion, waterproof, suitable for indoor and outdoor environments
- Treated glass with excellent light transmittance, defog, and dust repellent
Explosion-proof for Hazardous Locations
This explosion-proof explosion-proof is engineered for hazardous locations where standard equipment cannot operate safely. Certified for Class I Division 1 and Division 2 environments, it meets ATEX and IECEx standards for oil & gas, chemical, mining, and offshore installations.
Explore the full Veilux range of explosion-proof security cameras for your industrial security requirements.
All Veilux products comply with international IECEx standards for hazardous area certification.
Certifications & Compliance Standards
This explosion-proof explosion-proof complies with international safety standards including ATEX Directive 2014/34/EU for European hazardous area equipment and IECEx system certification for global acceptance. The product meets NEC Article 500 classification requirements for Class I Division 1 and Division 2 hazardous locations in North America, ensuring safe operation in environments containing flammable gases and vapors. All certifications are maintained through regular third-party audits by accredited testing laboratories.
Industrial Applications
Designed for the most demanding industrial environments, this explosion-proof is used in oil and gas refineries, petrochemical processing facilities, chemical manufacturing plants, pharmaceutical production areas, offshore platforms, and underground mining operations. It delivers reliable performance in Zone 1 and Zone 2 areas under IEC 60079, and in Class I Division 1 and Division 2 locations. Facility managers and HSE engineers rely on Veilux explosion-proof solutions to maintain safety and security in hazardous environments without compromising operational efficiency.
Why Choose Veilux?
Veilux has over 15 years of expertise designing explosion-proof security and monitoring equipment for hazardous environments. Our engineering team works directly with oil and gas operators, safety engineers, and facility managers to develop products that meet the most stringent safety and performance requirements. Every Veilux explosion-proof is backed by comprehensive technical support, detailed installation documentation, and global certification coverage to simplify procurement and compliance verification for international projects.
Key Features
- Certified explosion-proof motor for Zone 1 / Class I Division 1 environments
- ATEX, IECEx, and UL listed explosion-proof motor for global compliance
- Rugged industrial-grade construction for harsh environments
- Wide operating temperature range for extreme conditions
For technical specifications, certifications, and pricing on this explosion-proof motor, browse the full Veilux explosion-proof product range or contact our hazardous area specialists.
Explosion-proof Motor: Certifications and Compliance Standards
This explosion-proof motor meets the most stringent international hazardous area standards, ensuring safe operation in explosive atmospheres worldwide.
- ATEX Directive 2014/34/EU: Certifies this explosion-proof motor for Zone 1 and Zone 2 hazardous areas in Europe.
- IECEx System: Internationally recognised certification for this explosion-proof motor across 60+ countries.
- UL/cUL Listed: North American approval for Class I Division 1 and Division 2 environments.
- NFPA 70 / NEC Compliant: Meets National Electrical Code requirements for hazardous locations.
- IP66 / IP67: Dust-tight and waterproof ingress protection for harsh industrial environments.
Industries Using This Explosion-proof Motor
This explosion-proof motor is widely deployed across oil and gas refineries, petrochemical plants, offshore platforms, pharmaceutical facilities, grain elevators, paint spray booths, and wastewater treatment facilities. For detailed explosion-proof motor compliance guidance, refer to IEC international standards and NFPA codes.
Contact Veilux for custom explosion-proof motor configurations, bulk pricing, and technical certification documentation.
All equipment in this category meets the rigorous safety requirements for classified hazardous locations. Independent certification to ATEX, IECEx, and UL standards verifies that each unit has been tested for use in explosive atmospheres found in petrochemical facilities, offshore platforms, grain handling operations, and chemical processing plants. These certifications are renewed on a defined schedule to reflect any design changes and to maintain compliance with evolving international standards.
Proper product selection depends on your site classification, mounting requirements, and operating environment. Class I Division 1 and Zone 1 environments demand the highest level of enclosure protection, while Division 2 and Zone 2 locations may permit designs with a lower protection level. Working with a certified hazardous-area specialist before finalising your specification helps ensure the installation meets both local electrical codes and applicable international standards without over-specifying the hardware.
Professional installation is strongly recommended for all hazardous-area equipment. Installers experienced with NEC Article 500 and IEC 60079 can verify that cable entries, conduit seals, and grounding connections are completed correctly and documented for compliance records. Veilux supplies full technical documentation, certified installation drawings, wiring diagrams, and post-installation support for every product in our catalog at no additional charge.
| CERTIFICATIONS | |
| Ex-Level | ATEX II 2G Ex d IIC T6 Gb II 2D Ex tb IIIC IP68 T80°C Db |
| CAMERA | |
| Imaging Sensor | 1/2.8” Progressive Scan CMOS |
| Signal System | PAL/NTSC |
| Minimal Illumination | Color: 0.05Lux @ (F1.6, AGC ON) |
| BW: 0.01Lux @ (F1.6, AGC ON) | |
| Day/Night | ICR auto-switch |
| Electronic Shutter | 1/1S ~ 1/30,000S |
| Resolution Ratio | 50HZ: 25fps (1920×1080) 60HZ: 30fps (1920×1080) |
| 50HZ: 25fps (1280×720) 60HZ: 30fps (1280×720) | |
| White Balance | 1/2 Auto / indoor / outdoor / manual / sodium lamp / fluorescent lamp |
| DNR | 3D |
| IR | |
| IR Wavelength | 808nm |
| Light Angle | 30° |
| IR Range | 50m, 100m (optional) |
| LENS | |
| Focal Distance | 4.7-84.6mm, 18x |
| Aperture | F1.6-F3.5 |
| Horizontal View Angle | 58.3-3.2° (Wide-Tele) |
| Min-Working Distance | 10-1500mm (Wide-Tele) |
| Zoom Speed | About 2.7s (optical, Wide-Tele) |
| MENU CONTROL | |
| Exposure Mode | Auto Exposure / Aperture Priority / Shutter Priority / Manual Exposure |
| Focusing Mode | Auto /Manual /One Time Focusing |
| COMPRESSION | |
| Video Compression Standard | H.264 /MJPEG |
| Output Compression Rate | 32 Kbps~16Mbps |
| NETWORK | |
| Protocols | TCP/IP, HTTP, DHCP, DNS, DDNS, RTP, RTSP, PPPoE, SMTP, NTP, UPnP, SNMP, FTP, 802.1x, QoS, HTTPS, IPv6 (SIP, SRTP, Optional) |
| Intelligent Alarm | Motion detection, block alarm, memory full, memory fault |
| Memory | Support micro SD |
| INTERFACE | |
| Audio Input | Optional |
| Audio Output | Optional |
| Interface Protocols | ONVIF®, PSIA®, CGI® |
| GENERAL | |
| Inlet Hole Specifications | G-3/4 x 1 |
| Temperature Range | -40°C~60°C |
| Thermostat System | Optional |
| Relative Humidity | ≤5% (+25°C) |
| Atmospheric Pressure | 80kpa~106 kpa |
| Material | 304 stainless steel (Optional: 316, 316L) |
| Power | ADC12/AC220V (Optional) |
| Electrical Connection | 10-core composite cable |
| Installation Method | PTZ, Wall Hanging Bracket, Fixed Bracket, Pillar Base |
| Ingress Protection Level | IP68 |
| Dimensions | 380 x 144 x 232 (mm) |
| Weight | 7.2Kg (15.87lbs) |
Get a Free Customized Quote
Looking for pricing or have questions about this product? Fill out the form below and a member of our team will get back to you shortly.
